THE SLIP RESISTANCE INSPECTION SERVICES DIARIES

The Slip Resistance Inspection Services Diaries

The Slip Resistance Inspection Services Diaries

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it comes to ensuring safety in business, industrial, and residential spaces, slip resistance testing is an important factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and property owners alleviate risks and comply with safety requirements.

With state-of-the-art equipment such as the pendulum slip test device and moisture meter for concrete, we offer precise and independent slip testing services throughout Australia. Our knowledge covers ASTM F2170 compliance, R Ranking evaluations, P Rating tiles, and more, ensuring your floors satisfy the highest security standards.

Why Slip Resistance Testing is Essential


Slips and falls are among the leading causes of work environment and public injuries. Correct slip testing assists recognize hazardous surfaces before accidents occur. Whether you need wet pendulum test assessments or pendulum test for slip resistance, ATTAR provides accurate outcomes to boost security.

Key Services Provided by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 certified assessments.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Makes sure visibility for aesthetically impaired individuals.
- Complies with Australian accessibility standards.

4. On-Site & Laboratory Testing

- Slip test machine for accurate on-site assessments.
- Wet pendulum test for wet surface slip resistance.

Understanding Slip Resistance Ratings: R Ranking vs. P Ranking


When performing slip resistance testing, 2 essential classifications are used:.

- R Score (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently utilized in Europe.

- P Score (Pendulum Test - AS 4586)
Examines vibrant friction using a pendulum test slip resistance maker, extensively embraced in Australia.

ATTAR supplies independent slip testing to identify whether your flooring meets the required pendulum ranking tiles requirements.

The Significance of Concrete Moisture Testing


Excess moisture in concrete slabs can result in flooring failures, mold development, and adhesive deterioration. Our concrete moisture testing services include:.

> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to make sure ideal conditions for floor installations.

By discovering moisture issues early, we help prevent pricey repair work and make sure long-lasting floor covering efficiency.

Luminance Contrast for Ease Of Access Compliance


Appropriate luminance contrast is important for aesthetically impaired individuals to navigate spaces securely. ATTAR assesses:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.

Our evaluations make sure compliance with Australian Impairment Standards (AS 1428.1).

Why Choose ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where applicable).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Dependable Reporting.

For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, restaurants, and workplaces require safe floor covering to prevent client and employee injuries. Our pendulum slip test makes sure compliance with safety guidelines.

2. Industrial & Warehouse Facilities

High-traffic commercial environments need long lasting, slip-resistant floor covering. ATTAR's slip testing services help keep work environment safety.

3. Health Care & Aged Care Facilities

Medical facilities and assisted living home need to reduce slip threats. Our luminance contrast and slip resistance testing guarantee safe movement for patients and personnel.

4. Public Infrastructure

Walkways, train stations, and government buildings require independent slip testing to fulfill ease of access and security standards.

How ATTAR Carries Out Slip Resistance Testing


Action 1: Surface Evaluation

We evaluate flooring products and conditions (dry, wet, or infected).

Step 2: Pendulum Slip Test (AS 4663)

Utilizing a slip test machine, we measure the dynamic coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Replicates slippery conditions to examine real-world slip risks.

Step 4: Reporting & Compliance Accreditation

In-depth reports with R Rating or P Score tiles categories.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance method involves a swinging arm with a rubber slider that simulates a foot's motion. The test measures:.

- Slip Potential Worth (SPV).
- Pendulum ranking tiles category (P0 to P5).

Higher scores (P4/P5) suggest much better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related flooring failures can be costly. ATTAR's concrete slab moisture testing includes:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot check here checks.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With cutting-edge technology like the pendulum slip test and moisture meter for concrete, we deliver precise, independent, and certified testing services.

Guarantee your home meets safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By selecting ATTAR, you purchase independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security services. Let us assist you develop more secure, certified, and moisture-resistant environments.

Report this page